Measure heat release during self discharge. |
![]() |
The IBC-SD provides accurate and easy testing of heat output during self discharge of a single battery.
Heat occurring during discharging of batteries is largely due to their internal impedance. Characterisation of this heat at different operating temperatures is vital for efficient thermal mangement of cells in packs or modules.
IBC-SD is designed for self discharge studies and utilises an isothermal environment to control temperature. Each cell chamber within the calorimeter is precision controlled by Peltier elements. Feed back control allows the accurate measurement of heat flux.
Study battery
- Shelf life
Features
- Independent refernce chamber for each sample chamber (1 sample; 1 reference chamber)
- µW sensitivity calorimeter for self discharge studies
- Dynamic range up to 50 mW
- Windows based control software, USB connection
- Custom build option offering more cell chambers (contact THT for details)
Specification
Max Temperature (°C) 100
Min Temperature (°C) 5°C above ambient
Temperature Stability (°C) 0.001
Calorimeter chamber diameter (mm) 37 (customistable)
Calorimeter chamber depth (mm) 70 (customisable)
Number of sample chambers 1
Number of reference chambers 1
RMS Noise 1 µW
under controlled ambient conditions
Drift 5 µW / 24hrs
under controlled ambient conditions
Max heat detection 50mW
Heat capacity measurement capability No
Heat cut out No
External cycler terminals Only on custom cell holders
16 position Multipoint option No
Footprint (Width x Height x Depth) 18 x 20 x 18 inch
45 x 50 x 45 cm
Weight 34 lbs
15 kg
*Specification above subject to change
Sample test
Contact us to discuss your application / sample test needs
Click here to request sample information
Request Information
I'm interested in the following services
NB. Information submitted to Thermal Hazard Technology will not be distributed outside of the company without the express permission of the third-party and will only be used to contact you to send relevant information.